Can a Bayesian decision support system automate insulin dosing for adults with type 1 diabetes?

Hormone Insight visual abstract summarising a Bayesian decision support system for insulin dosing in type 1 diabetes.

Clinical Bottom Line

Summary: In adults with type 1 diabetes and suboptimal glycemic control (HbA1c ≥ 7.5%), a Bayesian decision support system (DSS) delivering weekly basal and prandial insulin dose recommendations via a mobile application significantly improved glycemic control over 12 weeks compared to standard…

Summary: In adults with type 1 diabetes and suboptimal glycemic control (HbA1c ≥ 7.5%), a Bayesian decision support system (DSS) delivering weekly basal and prandial insulin dose recommendations via a mobile application significantly improved glycemic control over 12 weeks compared to standard care using multiple daily injections without DSS, though it was associated with a small increase in  mild hypoglycemic events.
PICO Description
Population Adults with type 1 diabetes using multiple daily insulin injections and suboptimal glycemic control (HbA1c ≥ 7.5%).
Intervention Bayesian decision support system (DSS) comprising a mobile application and insulin titration algorithm providing weekly basal and prandial insulin dose recommendations.
Comparison Standard care with multiple daily insulin injections and routine clinician-managed dose adjustments without decision support system.
Outcome DSS use over 12 weeks significantly improved glycemic control (reduction in HbA1c) compared to standard care. Intervention group experienced a small increase in mild hypoglycemic events but no increase in severe hypoglycemia.
RCT Nat Commun · 2025

Bayesian DSS for insulin dosing in type 1 diabetes

RCT · type 1 diabetes · 12 weeks

Trial design
Adults T1D, HbA1c ≥ 7.5% Enrolled & assessed RANDOMISED 1:1 DSS Bayesian DSS app n = 42 Control Bolus calculator n = 42 Change in HbA1c from baseline
Change from baseline — both arms
% HbA1c Baseline Week 12 -0.40% (95% CI -0.75 to -0.05) DSS Control
DSS HbA1c
8.6→8.1%
p=0.0002
Control HbA1c
8.6→8.5%
p=0.22
Treatment effect
-0.40%
p=0.025
Severe hypo / DKA
0
both arms
⬡ Bottom Line

A Bayesian decision support system lowered HbA1c by 0.40% versus a non-adaptive bolus calculator over 12 weeks, with no severe hypoglycemia or ketoacidosis.

Source: Kobayati, Alessandra, et al. “A Bayesian decision support system for automated insulin doses in adults with type 1 diabetes on multiple daily injections: a randomized controlled trial.” Read article here.